CycleGard CGT450-2060, Steam Primary Low Water Cut-Off w/ Auto Reset for Tankless Coil Boilers, 120V
Hydrolevel CGT450-2060 is a 120V low water cut-off w/ auto reset and intermittent level test (ILT), designed for use as a primary LWCO control on steam boilers w/ tankless coil. Burner circuit contacts open after 15 second delay in a low water condition. Delay prevents short cycling caused by momentary fluctuations in the boiler water level. Automatically restarts burner circuit 30 seconds after water reaches the probe, allowing optional water feeder to raise water level above the probe. ILT removes power from the burner circuit and monitors settled (true) water level every 20 minutes (interval) for 60 seconds (duration) for added protection.
Unlike with standard CG450 models, the CGT450 suspends operation of the ILT if the boiler is receiving a call for domestic hot water - this ensures continued burner operation during a demand for hot water.

Technical Specifications:
  • System Type: Steam Boilers w/ Tankless Coil
  • Reset: Automatic
  • Connection: 3/4" NPT
  • Electrical Specs: 120V, 60 Hz, 4.2 VA (Power Consumption); SPDT (Relay Type), NEMA 1 Enclosure
  • Switching Capacity: 5.8 FLA, 34.8 LRA
  • Max Steam Pressure: 15 psi


Features:
  • Intermittent Level Test (ILT) for maximum protection of foaming boilers
  • Designed for residential and commercial steam boilers with DHW tankless coil
  • Optional water feeder connection
  • 15-second off-time burner shut down delay prevents short-cycling due to surging and priming
  • 30-second on-time delay allows to fill water above probe to a safe level
  • Intermittent Level Test feature monitors settled water every 20 minutes for 60 seconds to protect from false signals caused by foam
  • Optional SmartCycle feature restarts ILT sequence every time the burner fires
  • Front access cover, electrical knock-outs and a pigtail lead for easy wiring
  • LED indicators for ILT and low water
  • Direct boiler mounting - no blowdown or moving parts
  • Solid state circuitry for top-level performance and reliability

Write a review

Please login or register to review

CycleGard CGT450-2060, Steam Primary Low Water Cut-Off w/ Auto Reset for Tankless Coil Boilers, 120V

  • Views: 197
  • Brand: Hydrolevel
  • Model: CGT450-2060
  • MPN: 45-480-2060
  • Availability: 5 - 7 Days
  • Usually ships: Upon availability
  • $ 245.95

Tags: CycleGard CGT450-2060, Steam Primary Low Water Cut-Off, Auto Reset, Tankless Coil Boilers, 120V, LWCO, Boiler Water Level Control, Auto Reset LWCO, Steam Boiler Safety, CycleGard LWCO